# Secure IT/OT Convergence Through Physical Boundary Enforcement

Convergence delivers operational efficiency but destroys the air gap that protected industrial systems for decades. Control restores the physical boundary while preserving the data flows that convergence enables.

Back to Control: https://fire-vault.com/solutions/control

Image: Corridor of offline storage racks inside a Firevault bunker (https://fire-vault.com/assets/hero-square-bunker-B6Y7Qt9r.jpg)

The exposure in numbers

01

Of OT environments now have some IT network connectivity

91% Of OT environments now have some IT network connectivity

02

Persistent IT-to-OT network paths during production

Zero Persistent IT-to-OT network paths during production

03

Separation between IT and OT management planes

Physical Separation between IT and OT management planes

04

IEC 62443 zone and conduit compliance evidence

Full IEC 62443 zone and conduit compliance evidence

The Threat

## Convergence creates pathways that industrial systems were never designed to defend.

01

### Eroded Air Gaps

The physical separation that protected OT systems for decades has been replaced with firewalls and VLANs. These logical controls are bypassed through misconfigurations, credential theft, and zero-day vulnerabilities.

02

### Legacy System Exposure

Industrial control systems running decades-old software are now reachable from IT networks. These systems cannot be patched, cannot run endpoint protection, and were never designed for network-connected operation.

03

### Shared Management Planes

IT and OT often share authentication infrastructure, jump servers, and management tools. A compromise of the IT management plane provides direct access to OT control systems.

Threat Response

> You cannot firewall your way to an air gap. If a packet can traverse from your IT network to your OT environment, the boundary exists only in your network diagram, not in reality.

The Scenario

### Scenario: IT Compromise Reaching Industrial Control Systems

A water treatment facility connects its SCADA systems to the corporate IT network for remote monitoring and reporting. An attacker compromises a corporate workstation through a phishing email and discovers the jump server used for SCADA access. Using harvested credentials, they traverse from the IT network to the OT environment, gaining access to programmable logic controllers that manage chemical dosing. With Control, the IT-to-OT boundary is physically enforced. Data flows from OT to IT for monitoring occur through the Transfer module during scheduled windows, but there is no persistent path from IT into the OT environment. The jump server is physically disconnected from OT infrastructure outside authorised maintenance windows.

"We had a firewall between IT and OT with 47 rules. Our penetration testers traversed it in 3 hours. The only separation that would have stopped them was physical disconnection."

IT-to-OT crossover

## How Control stops IT incidents bleeding into OT.

IT and OT convergence is efficient, but it gives an IT compromise a direct road into safety-critical control systems. Control keeps the convergence operational without letting an IT incident become a process-safety incident.

Mapped to ATT&CK for ICS tactics (TA0108 Initial Access, TA0109 Execution, TA0106 Lateral Movement, TA0107 Inhibit Response Function) and IEC 62443 zone and conduit requirements.

1. ST 01
   IT Foothold
   TA0001
   ◤ Attacker
   Compromises a corporate endpoint or engineering workstation that also has a path into the OT network.
   ◢ Control breaks it
   The conduit between IT and OT is physically severed unless an authorised operational window is open.
   Image: FV-Firebreak module icon (https://fire-vault.com/assets/firebreak-icon-7zSCkB1t.png)
   Firebreak
   Image: FV-Isolate module icon (https://fire-vault.com/assets/isolate-icon-B9t8fl3o.png)
   Isolate
   ✕ Break here
2. ST 02
   Crossover Attempt
   TA0108
   ◤ Attacker
   Uses jump hosts, historians or engineering tooling to step across the IT-OT boundary.
   ◢ Control breaks it
   Cross-zone access becomes a named Relay session with explicit approval, scope and time limit.
   Image: FV-Relay module icon (https://fire-vault.com/assets/relay-icon-CVhJDRO7.png)
   Relay
   Image: FV-Lock module icon (https://fire-vault.com/assets/lock-icon-UU3vOaKE.png)
   Lock
   Image: FV-Validate module icon (https://fire-vault.com/assets/vault-icon-CD3Pv4ri.png)
   Validate
   ✕ Break here
3. ST 03
   OT Reconnaissance
   TA0102
   ◤ Attacker
   Enumerates PLCs, RTUs and HMIs to understand the process before acting.
   ◢ Control breaks it
   Discovery is contained within the level the session was scoped to. Field zones are not reachable as a side effect.
   Image: FV-Isolate module icon (https://fire-vault.com/assets/isolate-icon-B9t8fl3o.png)
   Isolate
   ✕ Break here
4. ST 04
   Inhibit Safety Response
   TA0107
   ◤ Attacker
   Tries to disable interlocks, alarms or safety instrumented systems so a destructive command can land.
   ◢ Control breaks it
   Safety-related changes require Execute with multi-party approval. The safety instrumented system stays beyond casual reach.
   Image: FV-Execute module icon (https://fire-vault.com/assets/execute-icon-kJl5Gtmk.png)
   Execute
   Image: FV-Validate module icon (https://fire-vault.com/assets/vault-icon-CD3Pv4ri.png)
   Validate
   Image: FV-Lock module icon (https://fire-vault.com/assets/lock-icon-UU3vOaKE.png)
   Lock

Outcome · outcome block

An IT compromise stays in IT. The operational process keeps running and the safety layer is never quietly disarmed.

Modules & symbols

Image: FV-Firebreak module icon (https://fire-vault.com/assets/firebreak-icon-7zSCkB1t.png)
Firebreak Physical sever

Image: FV-Isolate module icon (https://fire-vault.com/assets/isolate-icon-B9t8fl3o.png)
Isolate Zone boundary

Image: FV-Relay module icon (https://fire-vault.com/assets/relay-icon-CVhJDRO7.png)
Relay Time-bound path

Image: FV-Lock module icon (https://fire-vault.com/assets/lock-icon-UU3vOaKE.png)
Lock Named access

Image: FV-Validate module icon (https://fire-vault.com/assets/vault-icon-CD3Pv4ri.png)
Validate Integrity check

Image: FV-Execute module icon (https://fire-vault.com/assets/execute-icon-kJl5Gtmk.png)
Execute Approved action

✕

Break here Chain severed by Firevault

◤

Attacker step MITRE ATT&CK tactic

Featured In

Read about Firevault on TechRadar Pro: https://www.techradar.com/pro/uk-startup-put-physical-disconnect-switch-in-its-cloud-storage-offering-to-mitigate-ransomware-attacks-but-will-that-be-enough
Read about Firevault on Yahoo Finance: https://uk.finance.yahoo.com/news/firevault-launches-help-businesses-directors-074500961.html
Read about Firevault on Channel Insider: https://www.channelinsider.com/security/tools-and-platforms/firevault-security-offline-platform-offering/
Read about Firevault on Security Buyer: https://securitybuyer.com/uk-cybersecurity-startup-launches-firevault/
Read about Firevault on SecurityBrief: https://securitybrief.com.au/story/firevault-unveils-offline-digital-vault-to-combat-rising-cyber-risks

Capabilities

## What you get with every deployment

01

### Physical Boundary Enforcement

The IT/OT boundary is enforced through physical disconnection, not firewall rules. No misconfiguration, credential theft, or zero-day can bypass a path that does not exist.

02

### One-Way Data Diodes

Monitoring data flows from OT to IT through controlled transfer mechanisms that prevent any return path from IT into the OT environment.

03

### Separate Management Planes

IT and OT management infrastructure exists on physically separate networks. Compromise of IT management systems provides no path to OT control systems.

04

### Emergency OT Isolation

A single authorised command physically severs all IT/OT connections, allowing OT systems to continue safe operation while the IT compromise is contained.

05

### Conduit Activity Logging

Every data transfer and maintenance session across the IT/OT boundary is logged on physically disconnected storage for compliance and forensic purposes.

06

### IEC 62443 Compliance

Physical zone and conduit architecture maps directly to IEC 62443 requirements, with automated evidence generation for audit and certification.

Demo to Live

## Adoption Guide

Step 1

#### Convergence Point Audit

Map every connection between IT and OT environments, including shared management infrastructure, jump servers, historian links, and vendor access paths.

Step 2

#### Zone and Conduit Design

Design physically separated zones aligned to the Purdue model with controlled conduits for each authorised data flow and maintenance path.

Step 3

#### Non-Critical System Pilot

Deploy physical boundary enforcement on a non-critical OT segment, testing monitoring data flows, maintenance windows, and emergency isolation procedures.

Step 4

#### Full OT Deployment

Extend to all IT/OT boundaries with automated compliance evidence generation, continuous conduit monitoring, and integration with existing SCADA management.

Step 1

#### Convergence Point Audit

Step 2

#### Zone and Conduit Design

Step 3

#### Non-Critical System Pilot

Step 4

#### Full OT Deployment

Organise a Demo: https://fire-vault.com/contact

## Explore More

### Control for Utilities

Physical isolation for power grid and utility SCADA.

Learn more about Control for Utilities
https://fire-vault.com/control-for-utilities

### Management Plane Exposure

Isolate management interfaces from production networks.

Learn more about Management Plane Exposure
https://fire-vault.com/control-for-management-plane

### IEC 62443 Compliance

Industrial automation security and Purdue model compliance.

Learn more about IEC 62443 Compliance
https://fire-vault.com/solutions/control/frameworks/iec-62443

Questions

## Frequently Asked

## Structured data

```json
[
  {
    "@context": "https://schema.org",
    "@type": "Organization",
    "@id": "https://fire-vault.com/#organization",
    "name": "Firevault",
    "legalName": "Firevault Limited",
    "url": "https://fire-vault.com",
    "logo": {
      "@type": "ImageObject",
      "url": "https://fire-vault.com/logo.png",
      "width": 200,
      "height": 60
    },
    "foundingDate": "2025-03",
    "description": "Protect what matters with Offline Secure Storage and control what moves with Control by Firevault. Physically disconnected, always reachable by you.",
    "address": {
      "@type": "PostalAddress",
      "addressCountry": "GB",
      "addressLocality": "United Kingdom"
    },
    "contactPoint": [
      {
        "@type": "ContactPoint",
        "contactType": "customer service",
        "email": "hello@fire-vault.com",
        "availableLanguage": "English",
        "areaServed": [
          "GB",
          "EU",
          "US",
          "AE"
        ]
      },
      {
        "@type": "ContactPoint",
        "contactType": "sales",
        "email": "sales@fire-vault.com",
        "availableLanguage": "English",
        "areaServed": [
          "GB",
          "EU",
          "US",
          "AE"
        ]
      }
    ],
    "founder": [
      {
        "@type": "Person",
        "name": "Mark Fermor",
        "jobTitle": "Founder, CTO and CMO"
      },
      {
        "@type": "Person",
        "name": "David Bailey",
        "jobTitle": "Founder and CEO"
      }
    ],
    "areaServed": [
      "United Kingdom",
      "Europe",
      "United States",
      "Middle East"
    ],
    "sameAs": [
      "https://www.linkedin.com/company/firevault",
      "https://x.com/firevaultuk"
    ],
    "slogan": "Disconnect to Protect",
    "brand": [
      {
        "@type": "Brand",
        "name": "Offline Secure Storage"
      },
      {
        "@type": "Brand",
        "name": "Control by Firevault"
      },
      {
        "@type": "Brand",
        "name": "Firebreak"
      }
    ],
    "knowsAbout": [
      "Offline Secure Storage",
      "Physically disconnected data storage",
      "Physical Air Gap Data Protection",
      "Ransomware Protection",
      "Ransomware recovery",
      "3-2-1-1-0 backup rule",
      "AI kill switch",
      "Operational technology security",
      "Critical national infrastructure resilience",
      "Data Sovereignty",
      "GDPR Compliance",
      "NIS2 Compliance",
      "DORA Compliance",
      "NCSC Cyber Assessment Framework"
    ]
  },
  {
    "@context": "https://schema.org",
    "@type": "WebSite",
    "@id": "https://fire-vault.com/#website",
    "name": "Firevault",
    "alternateName": [
      "Firevault",
      "Firevault UK",
      "Firevault Limited"
    ],
    "url": "https://fire-vault.com",
    "publisher": {
      "@id": "https://fire-vault.com/#organization"
    },
    "inLanguage": "en-GB",
    "description": "Protect what matters with Offline Secure Storage and control what moves with Control by Firevault. Physically disconnected, always reachable by you.",
    "potentialAction": {
      "@type": "SearchAction",
      "target": {
        "@type": "EntryPoint",
        "urlTemplate": "https://fire-vault.com/learn?q={search_term_string}"
      },
      "query-input": "required name=search_term_string"
    }
  },
  {
    "@context": "https://schema.org",
    "@type": "WebPage",
    "@id": "https://fire-vault.com/control-for-it-ot-convergence#webpage",
    "url": "https://fire-vault.com/control-for-it-ot-convergence",
    "name": "Secure IT/OT Convergence",
    "description": "Safely manage IT/OT convergence by enforcing a strong, physical boundary between your information technology and operational technology networks. Discover.",
    "isPartOf": {
      "@id": "https://fire-vault.com/#website"
    },
    "about": {
      "@id": "https://fire-vault.com/#organization"
    },
    "primaryImageOfPage": {
      "@type": "ImageObject",
      "url": "https://fire-vault.com/images/og/og-base-platform.jpg"
    },
    "inLanguage": "en-GB",
    "breadcrumb": {
      "@id": "https://fire-vault.com/control-for-it-ot-convergence#breadcrumb"
    }
  },
  {
    "@context": "https://schema.org",
    "@type": "BreadcrumbList",
    "@id": "https://fire-vault.com/control-for-it-ot-convergence#breadcrumb",
    "itemListElement": [
      {
        "@type": "ListItem",
        "position": 1,
        "name": "Home",
        "item": "https://fire-vault.com"
      },
      {
        "@type": "ListItem",
        "position": 2,
        "name": "Secure IT/OT Convergence",
        "item": "https://fire-vault.com/control-for-it-ot-convergence"
      }
    ]
  }
]
```